Alterations · outdoor electrics

Outdoor lighting installation, outside sockets and pond supplies.

New outdoor lights get their own circuit, with weatherproof fittings and a switch or a motion sensor. I also fit outside sockets and pond pump supplies, and replace tired PIR floodlights on the wiring that's already there.

  • £2m public liability insurance
  • Work carried out to BS 7671:2018+A4:2026
  • Fire alarm design, installation and commissioning to BS 5839-1

Outdoor lighting on its own circuit

A new lighting circuit starts at the consumer unit and runs out to the fittings in cable suited to the outdoors, buried and marked, or fixed where nothing will knock it. The fittings need an IP rating that suits where they go. A lamp tucked under the eaves sees far less weather than a post light beside the drive.

The standard job is one circuit and up to four fittings, switched by hand or by a PIR sensor. You can buy the fittings yourself, or I can supply them and we quote for them with the job.

Decide early how the lights should switch. A PIR sensor turns a light on when something moves and off after a set time, good for a back door or a drive. A dusk sensor keeps a porch light on through the dark.

Plug-in garden light kits at extra-low voltage bring their own transformer, and the transformer still needs a socket, which outdoors should be weatherproof and RCD-protected.

On the coast, salt in the air is hard on cheap metal fittings. Lights sold for exposed spots cost more and last longer, and I'd rather fit something once. I'll keep the cost down where I can, but not with a light that rusts by spring.

Security lights and floodlights

Swapping an old PIR floodlight for a new one on the existing wiring is a small priced job, standard floodlight included, as long as it's at ladder height.

Fixed lighting outside a house comes under Part P. Changing a fitting on an existing outdoor circuit is not notifiable in England, though Approved Document P still expects the work to be tested and certificated to BS 7671. A brand new lighting circuit is notifiable.

Aim a floodlight down onto your own drive, and set the sensor so passing cars and cats don't keep tripping it. One that lights up a neighbour's bedroom can count as a statutory nuisance under section 79 of the 1990 Environmental Protection Act, and councils investigate complaints about it.

Floodlights with a camera built in are wired like any other light. Recording that covers the whole property needs a camera system with a recorder.

Outdoor socket installation

An outside socket saves feeding a lead through the window for the mower or the pressure washer. Most people ask for one in spring, when the garden work starts.

For anything left plugged in outside, such as Christmas lights, choose a socket whose lid closes over the plug.

The usual job is a single weatherproof double socket on an outside wall, wired from a circuit indoors that runs nearby. BS 7671 asks for RCD protection on sockets and on equipment used outdoors, and this socket has it.

Because it extends an existing circuit and sits outside any special location, an outdoor socket is not notifiable work in England. I test it and give you a Minor Electrical Installation Works Certificate for it.

If the socket is for a plug-in hot tub, check the tub's instructions first, because the maker says whether a socket is acceptable and where. Wiring a hard-shell hot tub is another job altogether, with a circuit to itself.

Pond pump and fountain supplies

A pond pump supply is RCD-protected, with a weatherproof isolator near the pond, so the pump can be switched off before anyone reaches in to clear the filter. Part P covers it, and Approved Document P names pond pumps in so many words.

Fountains come under Section 702 of BS 7671, the same section as swimming pools, because wet skin makes a shock far more dangerous.

Some pond pumps run at extra-low voltage from a transformer kept back from the water. Larger ones run at mains voltage and rely on the RCD, and the pump's instructions say which yours is. The cable back to the house is buried and its route marked, whatever the pump.

If the pond is near a shed or summerhouse that already has its own supply, the pump can sometimes be fed from that board instead of running a fresh cable all the way from the house.

Prices

Outdoor lighting and socket prices

A longer cable run, more fittings or a socket down the bottom of the garden is priced in writing once I've walked round.

Outside lights, sockets and pond supplies
JobPriceIncludesPriced
External lighting circuitNew outdoor lighting circuit with up to four IP-rated fittings on a switch or PIR, cable run under 20 m, fittings customer-supplied or quotedfrom £130Circuit · Fittings connected · Testing · Certificateper circuit
Replace a PIR security floodlightLike-for-like replacement of a PIR floodlight on the existing supply, ladder height, with a standard floodlight we supply; anything not on an existing supply is quotedfrom £85Standard floodlight supplied · Floodlight replaced · Testingper job
Outdoor double socketOne weatherproof RCD-protected double socket on an external wall within 3 m of an existing circuitfrom £150Socket · RCD protection · Testing · Minor works certificateper job
Pond pump or fountain supplyRCD-protected outdoor supply with a weatherproof isolator for a pond pump or fountain, to BS 7671 (Section 702 for fountains)from £130Supply · Isolator · Testing · Certificateper supply

Every price is a "from" price for a standard job, priced per job, never by the hour. Anything not on the list is quoted in writing after a free survey. Prices include travel to your address, and a merchant run if the job needs anything out of the ordinary: no travel charge on top. No VAT to add.

Book a free surveyCertificate issued before the final invoice.
Process

How an outdoor job runs

  1. Tell us what you need

    What needs light or power, and where. Photos of the wall help.

  2. Walk the garden

    I work out where the cable can run, where the fittings go and what the board can take.

  3. Pricing it up

    A written, fixed quote within two working days of the survey.

  4. Fitting and testing

    Certificate issued before the final invoice.

On every job

What we promise

  • Certificate issued before the final invoice.
  • A written, fixed quote within two working days of the survey.
  • The same electrician from survey to sign-off.
  • Work tested to BS 7671:2018+A4:2026.
  • 24-month workmanship guarantee on top of your statutory rights.
  • 12-month guarantee on the parts we supply, on top of your statutory rights; fittings you supply carry their maker's warranty.