Commercial · guesthouses and HMOs

HMO electrical requirements for landlords and guesthouse owners.

An HMO is its tenants' home, so the landlord's electrical safety duties apply, and fire safety law covers the shared parts. A guesthouse takes paying guests rather than tenants, and fire safety law sets what it needs.

  • £2m public liability insurance
  • Work carried out to BS 7671:2018+A4:2026
  • Fire alarm design, installation and commissioning to BS 5839-1

What electrical certificate does an HMO need?

An HMO let as its tenants' homes needs a condition report. The Electrical Safety Standards regulations make the landlord have the installation inspected and tested by a qualified person every 5 years at most, or earlier if the most recent report says so.

Rooms let on licences are caught as well, because the rules count a licence to occupy as a tenancy. A lodger who shares a kitchen or a bathroom with you or your family is the exception.

Every tenant gets a copy of the report, and the council can ask for one. If the report finds work is needed, it has to be done within 28 days, or sooner where the report sets a shorter deadline.

The HMO management regulations used to have an electrical inspection rule of their own, which went when these standards came in.

Getting into every room

Every let room has sockets and lighting on the circuits being tested, so give the tenants notice of the date and sort out the keys before the day.

If a tenant won't let anyone in, a landlord who has taken all reasonable steps isn't in breach, and the regulations don't expect a court case to get access.

What an HMO licence adds

Larger HMOs need a council licence, and every licence carries the same safety conditions. One is that each electrical installation is in proper working order and safe for continued use, with a declaration to the council when it asks for one.

The conditions also require a smoke alarm on each storey with living accommodation, kept in working order, and a carbon monoxide alarm in any room with a fixed combustion appliance other than a gas cooker.

Some councils license smaller HMOs too, through additional or selective licensing schemes.

Do HMOs need AFDDs?

For new work, yes. BS 7671 requires arc fault detection devices on the socket circuits of HMOs and recommends them elsewhere. The rule came in with the 2022 amendment and stays in the current edition, BS 7671:2018+A4:2026.

An AFDD watches for the electrical signature of arcing, the sparking you get at a loose terminal or a damaged cable, which an ordinary circuit breaker or RCD is not built to detect.

An HMO wired before then isn't unsafe just because it has none. BS 7671 says an older installation can fall short of the current edition without being unsafe, and the condition report judges it on safety.

When I put new socket circuits or a new board into an HMO, the AFDDs go in the quote.

Fire alarms in shared houses

The alarm system an HMO needs depends on its size and how the rooms are let. Councils work from national housing fire safety guidance and BS 5839-6, and a small shared house is usually expected to have interlinked mains smoke alarms, with a heat alarm in the kitchen.

Taller houses and bedsit-style HMOs step up to more detection, and the largest to a panel system with call points. A panel system needs servicing through the year. I can carry out the once-a-year inspection, and any other servicing it needs is quoted separately.

Smoke and heat alarms linked to each other are what I fit in smaller houses, and the standard job has its own from price.

Guesthouses and B&Bs

Fire safety law covers a guesthouse, and the duties sit with the responsible person, usually the owner or whoever runs the place.

The Home Office guide for small guesthouses and B&Bs says the fixed wiring should have an inspection and test at least once every 5 years, by a qualified electrical contractor.

That guide also asks for linked smoke and heat alarms in every area where a fire might start, mains powered with a battery standby, and emergency escape lighting on hallways and stairs. In the very smallest premises, rechargeable torches that come on by themselves can be enough.

Bigger guesthouses come under the government's wider guide for sleeping accommodation, which covers caravan holiday parks too.

Emergency lights in a guesthouse need their annual test like anywhere else, and it's a separate job with its own price.

Condition report prices

An HMO's condition report is priced per property, and a guesthouse's is on the home price.

Prices

Prices for HMOs and guesthouses

We quote for a building with more boards or circuits than a row allows.

Condition report, alarm and lighting prices
JobPriceIncludesPriced
Electrical condition report (EICR), domesticSingle-board domestic installation, up to 10 circuits, accessible board and accessoriesfrom £150Full inspection and test · Coded report to BS 7671:2018+A4:2026 · Plain-English summaryper property, up to 10 circuits
Interlinked smoke and heat alarms (home)Three mains-powered interlinked alarms with battery backup (BS 5839-6 Grade D1) in a two-storey house: hall, landing, kitchen heat alarmfrom £495Alarms · Wiring · Testing · Certificateper system
Fire alarm annual inspection and testOne yearly inspection and test of a small fire alarm system (up to 20 devices), with a logbook entry and certificate. It is one visit a year, not the full routine servicing a commercial system needs; that is quoted separatelyfrom £495Inspection and test · Logbook entry · Certificateper visit, up to 20 devices
Emergency lighting annual testFull-duration (3-hour) annual test of up to 10 fittings on one site, logbook entry and certificatefrom £195Full-duration test · Certificate · Logbook entryper premises, up to 10 fittings

Every price is a "from" price for a standard job, priced per job, never by the hour. Anything not on the list is quoted in writing after a free survey. Prices include travel to your address, and a merchant run if the job needs anything out of the ordinary: no travel charge on top. No VAT to add.

Book an EICRfrom £150Certificate issued before the final invoice.
Process

Booking a report or an alarm job

  1. Get in touch

    Tell us whether it is a shared house or a guesthouse, and how many rooms and boards it has.

  2. Free survey

    For anything bigger than a standard job, I look round the house first.

  3. Fixed written quote

    A written, fixed quote within two working days of the survey.

  4. Test, then the report

    Certificate issued before the final invoice.

The electrician

Levi Pickering

Electrician

I inspect shared houses and guesthouses myself and write up every report.

LP Contract ServicesCredentials
Electrician
Levi Pickering
Qualifications
Apprentice-trained, time served
NVQ Level 3 Electrotechnical
AM2S
City & Guilds 2391-52 Inspection and Testing (initial and periodic)
18th Edition BS 7671, Amendment 4:2026 update
Solar PV and battery storage installation training
Insurance
£2m public liability insurance
Experience
10+ years
Bridlington · Scarborough · Hull
On every job

What we promise

  • Certificate issued before the final invoice.
  • A written, fixed quote within two working days of the survey.
  • The same electrician from survey to sign-off.
  • Work tested to BS 7671:2018+A4:2026.
  • 24-month workmanship guarantee on top of your statutory rights.
  • 12-month guarantee on the parts we supply, on top of your statutory rights; fittings you supply carry their maker's warranty.
Call Book a survey